Those who do not divert rainwater into the sewer system but instead return it to the ground at the point of precipitation are not only acting in an environmentally responsible manner but also relieve the burden on urban infrastructure, protect water bodies, and strengthen the local water cycle. Rainwater infiltration via an infiltration shaft is one of the most technically advanced and space-efficient methods: An infiltration shaft directs the water specifically into deeper, absorbent soil layers, thereby enabling decentralized infiltration even where near-surface soils are compacted or have low permeability. Those who understand the fundamentals of this technology can design and build systems that function reliably over the long term.
- What an infiltration shaft is and how it differs from other infiltration systems
- Which hydraulic and soil science principles determine the sizing
- Which standards, regulations, and official requirements apply
- How an infiltration shaft is structurally designed and which materials are suitable
- When an infiltration shaft is the right choice and when other forms of infiltration are preferable
- What preliminary work, soil investigations, and permitting procedures are required
- How operation and maintenance ensure that systems remain functional over the long term
- What typical design errors occur and how they can be avoided
What Is an Infiltration Well? Definition, Classification, and Distinctions
An infiltration shaft—also known in technical terminology as a rainwater infiltration pit or rainwater shaft—is a tubular or cylindrical structure installed in the ground that collects stormwater from paved surfaces and releases it in a controlled manner into the subsoil through its walls and base. Unlike an infiltration basin, which allows water to infiltrate over a wide area through the active soil zone, the well directs the water specifically into deeper soil horizons that are not accessible at the surface. This deep infiltration is the characteristic advantage of this design and, at the same time, the reason why it places special demands on soil suitability and construction.
Within the system of decentralized stormwater management, the infiltration shaft is used alongside surface infiltration, basin infiltration, basin-trench infiltration, and infiltration ditches. The choice between these systems depends on the available area, soil conditions, the connected catchment area, and local water regulations. The infiltration shaft is particularly suitable when the property area is limited, the near-surface soil has low permeability but deeper layers offer sufficient infiltration capacity, or when an underground solution is required for design or usage-related reasons.
It is important to distinguish this concept from the traditional septic tank for wastewater: The infiltration shaft for rainwater accepts only uncontaminated or slightly contaminated stormwater, never wastewater or combined sewer overflow. This separation is mandatory not only from a structural engineering perspective but also under water law. The discharge of wastewater into an infiltration shaft is generally prohibited in Germany and constitutes a violation of the Water Resources Act.
Hydraulic and Soil Science Principles of Rainwater Infiltration
The performance of an infiltration shaft depends directly on the permeability of the surrounding soil. The key parameter is the saturated hydraulic conductivity coefficient kf, measured in meters per second (m/s). It describes how quickly water flows through soil when it is completely saturated with water. For the infiltration of stormwater, DWA-A 138, the worksheet issued by the German Association for Water Management, Wastewater, and Waste—the central German regulatory framework for the planning, construction, and operation of decentralized infiltration systems—kf values between 1 × 10⁻⁶ m/s and 1 × 10⁻³ m/s are defined as suitable. Soils with higher kf values—that is, very coarse-grained gravels or sands—do infiltrate quickly, but offer little filtration capacity and can be problematic if there is direct contact with groundwater. Soils with lower kf values—that is, cohesive clays and silts—absorb water too slowly to operate a functional system.
The kf value is determined in the field through infiltration tests. Common methods include the so-called double-ring test or the simpler short-term infiltration test according to DWA-A 138, in which water is introduced into an excavated pit and the rate of decline is measured. Laboratory analyses of soil samples provide supplementary information but do not completely replace the field test, because the natural bulk density, stratification, and heterogeneity of the soil can hardly be accurately replicated in the laboratory. To ensure reliable design, professional planners always recommend conducting field tests at multiple locations on the property, as soils can vary significantly over small areas.
In addition to the kf value, the distance between the bottom of the shaft and the highest expected groundwater level is of crucial importance. DWA-A 138 generally requires a minimum distance of one meter between the lower edge of the infiltration system and the highest groundwater level. This safety margin protects the groundwater from direct contamination by pollutants that may be present in the seepage water and prevents the system from becoming hydraulically saturated when the groundwater level is high, which would cause it to lose its function. Determining the relevant groundwater level generally requires analyzing groundwater level data from the relevant authorities or conducting one’s own measurements over a sufficiently long period of time.
Standards, Regulations, and Water Law Requirements
Rainwater infiltration via a shaft is governed in Germany by a multi-layered regulatory framework. At the federal level, the Water Resources Act (WHG) provides the legal basis: It requires property owners in certain areas to infiltrate stormwater locally, provided this can be done without adversely affecting the public interest. The state water laws of the individual federal states specify these requirements and regulate permitting obligations as well as exceptions. In many federal states, the infiltration of stormwater from roof surfaces up to a certain size does not require a permit, provided that specific requirements regarding the location and design are met. For larger systems or under special site conditions, a permit or authorization under water law is required.
The technical cornerstone of the planning process is the aforementioned DWA-A 138 worksheet. It contains guidelines on site suitability, infiltration tests, hydraulic sizing, distance requirements from buildings, property lines, and traffic areas, as well as maintenance and operation. In addition, the Technical Rules for the Harmless Discharge of Collected Stormwater into Groundwater (TRENGW) issued by the State Working Group on Water (LAWA) must be observed; these rules specify requirements regarding the quality of the water to be discharged and the protection of groundwater. These regulations serve as a binding basis for professional planners; anyone deviating from them must demonstrate the equivalence of the chosen solution.
Another important practical consideration is which surfaces may be connected to an infiltration shaft. Roof surfaces made of uncoated metals such as copper, zinc, or lead can introduce heavy metals into the infiltrating water and are therefore generally not suitable for infiltration without pretreatment. Traffic areas, parking lots, and courtyards with elevated levels of pollutants from tire wear, fuels, or oils also require pretreatment—for example, via a sedimentation chamber or a light-liquid separator—before the water is discharged into the infiltration well. Roof surfaces made of tile, concrete, or coated materials are generally considered suitable for infiltration without pretreatment, provided there are no special contamination issues.
Structural Design: Materials, Sizing, and Installation
An infiltration well essentially consists of three elements: the inflow area with a sedimentation zone, the actual infiltration body, and the cover. The inlet area serves as a pre-treatment stage: coarse materials, leaves, and sediments are allowed to settle here before the water enters the infiltration area. An upstream sludge trap or sedimentation chamber is often used, which must be regularly maintained and emptied. This step is crucial for the longevity of the entire system because fine sediments cause the infiltration chamber to silt up over time, permanently reducing its performance.
The infiltration body itself is constructed from perforated concrete rings, perforated plastic pipes, or special infiltration shaft systems made of polyethylene (PE) or polypropylene (PP). Concrete rings with circumferential slits or holes are the classic design and are characterized by high durability and compressive strength. Plastic systems are easier to transport and install, but offer less margin for error if stored improperly or overloaded by soil pressure. The infiltration chamber is typically installed on a gravel bed of washed coarse gravel or crushed stone, which improves bottom infiltration and allows for even water distribution into the subsoil. The annular space between the manhole wall and the surrounding soil is also backfilled with gravel or crushed stone to promote lateral infiltration.
The manhole is dimensioned according to the calculation method specified in DWA-A 138. The key factors are the connected impervious area, the design rainfall (typically a rainfall event with a specific annual frequency, i.e., statistical recurrence interval), the soil’s kf value, and the manhole’s available storage volume. The storage volume bridges the period during which the inflow exceeds the current infiltration capacity and prevents overflow. A emergency overflow, which safely diverts water during extreme rainfall events, must always be provided in well-planned systems to prevent backflow and flood damage.
Distance requirements must be strictly adhered to during installation. DWA-A 138 recommends minimum distances of generally one meter from the property line, two meters from buildings without watertight basement walls, and greater distances from buildings with basements to prevent water damage to foundations. Sloped sites require special attention because infiltrated water can flow downhill and destabilize foundations or embankments. These distances are not merely bureaucratic formalities, but rather guidelines based on practical experience with damage cases.
When is an infiltration well the right choice?
The decision to use an infiltration shaft as a method of rainwater infiltration is always a site-specific consideration. The infiltration well is particularly suitable when the property area is insufficient for extensive infiltration systems such as basins or basin-trench systems; when the soil near the surface is relatively impermeable due to compaction, development, or natural composition, but deeper soil layers exhibit good kf values, or when a fully underground solution is required without restricting land use.
From an ecological perspective, trough infiltration and trough-trench systems are generally preferable to the shaft because they guide the water through the active soil zone, thereby enabling natural filtration and the biological degradation of pollutants. The infiltration shaft bypasses this filter zone, which places higher demands on the quality of the water being discharged. Where soil quality and land availability permit, the infiltration basin or infiltration basin-trench system should therefore be preferred. Nevertheless, the infiltration shaft remains an indispensable option in urban practice because the constraints in densely built-up areas often leave no alternative.
Infiltration shafts are not suitable for soils with kf values outside the recommended range, where the distance to the groundwater table is too small, in Zone I and II water protection areas (where infiltration systems are generally prohibited), in contaminated subsoil, and in areas with known risks of settlement due to soluble rocks such as gypsum or limestone, where infiltration can trigger subrosion—that is, underground dissolution and the formation of cavities.
Operation, Maintenance, and Common Design Errors
An infiltration shaft is not a maintenance-free system. Without regular maintenance, sedimentation chambers and inflow areas become silted up, and fine particles migrate into the infiltration body, clogging its walls and bottom. The result is a gradual decline in infiltration capacity, which is often not noticed until the shaft overflows during heavy rain or water pools on the surface. Experts recommend a visual inspection at least once a year, as well as cleaning the sedimentation area as needed—typically every one to three years. The infiltration body itself should be checked for blockages every five to ten years; if in doubt, infiltration capacity can be roughly estimated through a simple fill test.
One of the most common design errors is underestimating sediment load. Anyone who designs an infiltration shaft without a sufficiently sized pre-shaft or sediment trap creates a system that functions when new but becomes clogged with fine sediments within a few years. Another common mistake is selecting a site without adequate soil testing: Anyone who merely estimates the kf value or derives it from general soil maps risks designing a system that is either undersized or oversized. Neglecting the groundwater level also regularly leads to problems, especially in areas with groundwater levels that fluctuate significantly throughout the seasons.
A design flaw that occurs time and again in practice is the discharge of water from unsuitable surfaces without pretreatment. Anyone who directs water from a copper roof or a parking lot directly into the infiltration shaft endangers the groundwater and violates water law regulations. Pre-treatment is not an optional convenience, but a legal and technical requirement. Professional planners who incorporate these requirements into the design early on avoid costly retrofits and regulatory requirements.
Rainwater Infiltration in the Context of Urban Development and Climate Protection
Decentralized rainwater infiltration—and thus also the infiltration shaft as one of its implementation forms—is far more than a single technical measure. It is a building block of the “sponge city” strategy—the conceptual framework designed to enable cities to absorb, store, filter, and release stormwater gradually, rather than draining it away quickly. At a time when heavy rainfall events are becoming more frequent and intense, while heat waves increase evaporation and dry out the soil, returning rainwater to the local water cycle is becoming increasingly important.
Municipal drainage plans, zoning plans, and land development plans are increasingly incorporating infiltration systems as a mandatory component. Provisions for the infiltration of stormwater on private property are permitted in zoning plans under the Building Code and are utilized by municipalities to relieve the burden on sewer systems and support the natural water balance. The infiltration shaft is often the solution for properties where extensive systems cannot be implemented due to space or soil constraints.
For landscape architects and open-space planners, this means that rainwater infiltration via a shaft should not be treated as a secondary technical detail, but rather as an integral part of the design. The location of the well, its integration into the site profile, the design of the inflow paths, and its connection to other infiltration elements—such as basins, swales, or vegetated areas—determine whether a system functions reliably over the long term and is aesthetically compelling. Those who view stormwater management as a design task from the very beginning create open spaces that are robust, ecologically effective, and require minimal long-term maintenance.